Our firm sticks to the basic principle of "Quality is the life of your company, and status will be the soul of it" for Trauma Locking Plate, Anatomical Maxillofacial Trauma Palte, Micro Bone Screw, We are keeping durable small business relationships with additional than 200 wholesalers in the USA, the UK, Germany and Canada. For anyone who is intrigued in any of our products, make sure you experience free to speak to us.
Hot-selling Cranium 2 Holes Titanium Palte - Periprosthetic Fracture Plate – Shuangyang Detail:

(This frame is for reference only, the actual surgery depends on the fracture).

Frame detail:

In the parallel layout, put two 3mm bone screws in the radius shaft at the proximal end, and put two 3mm bone screws in the distal dorsal nodules. Mount the coupling X proximally and connect it with a straight post. Install a Coupling XI at the far end. Then use two rod to rod couplings VII and one Ф5 L180mm connecting rod (straight type) to connect all the components into a frame and finally lock. (In the operation, the needle block X and the needle block XIX should be used as guide for the parallel layout of the Bone screws) .

Features:  

1. Easy to operate, flexible combination, can build a three- dimensional stable external fixation system.
2. According to the adaptation symptoms, the stent can be freely assembled during the operation, and the components can be added to the frame at any time.
3. PEEK fix clamp help reduce the overall frame weight.
4. PEEK fix clamp has low developing degree, easy operation.
5. Carbon fiber connecting rod build elastic frame, to reduce stress concentration.

Recommended configurations:

Product Image

Order Code.

Product Name

Specification (mm)

Qty

detail (1)

20.10.0105180.300

Connecting rod (straight)

Ф5, 180mm

1

detail (2) 

20.20.0705201.400

Rod to rod coupling VII

2 holes Ф5

2

 detail (3)

20.20.1005401.400

Coupling X

4 holes Ф3

1

 detail (5)

20.30.0305101.400

30° Post

Ф5

1

 detail (4)

20.20.1105401.200

Coupling XI

4 holes Ф3

1

 detail (6)

19.32.513.0300801

Bone screw

Ф3.0×80mm

4

Femoral fractures, especially spiral fractures or those after stemmed arthroplasty, often need cerclage wire fixation to optimize the reduction of plate osteosynthesis.

Considering the excellent results already achieved in total hip arthroplasty, new implants must be at least as safe as currently used implants and lead to longer survival. The combination of titanium locking plates and titanium cerclage wire is a good option for surgery.

Till date, titanium periprosthetic fracture plate and titanium cerclage wires (titanium cable) are easy to use and are reliable for internal fixation and offer sufficient stability. Alternative devices such as cable buttons and others made of cobalt-chrome or titanium alloy are insufficient for strength and stability.

We call the combination of titanium locking plates and titanium cerclage wires as Titanium Binding System. This product in minimally invasive closed reduction and internal fixation of femoral fractures did not show any negative effects on fracture healing or the clinical course, compared to controls.

Titanium periprosthetic fracture plates have different stem designs and contact areas between the bone and implant. Therefore, the properties of primary and secondary fixation vary. Because of the growing number of different femoral stems used in clinical practice, there is no comprehensive classification system covering all implants. 

But titanium periprosthetic fracture plate should be avoided in patients with poor bone quality because of higher complication risk. 


Product detail pictures:

Hot-selling Cranium 2 Holes Titanium Palte - Periprosthetic Fracture Plate – Shuangyang detail pictures

Hot-selling Cranium 2 Holes Titanium Palte - Periprosthetic Fracture Plate – Shuangyang detail pictures

Hot-selling Cranium 2 Holes Titanium Palte - Periprosthetic Fracture Plate – Shuangyang detail pictures

Hot-selling Cranium 2 Holes Titanium Palte - Periprosthetic Fracture Plate – Shuangyang detail pictures

Hot-selling Cranium 2 Holes Titanium Palte - Periprosthetic Fracture Plate – Shuangyang detail pictures


Related Product Guide:

Our organization sticks to your principle of "Quality may be the life of your organization, and reputation will be the soul of it" for Hot-selling Cranium 2 Holes Titanium Palte - Periprosthetic Fracture Plate – Shuangyang, The product will supply to all over the world, such as: Atlanta, Milan, St. Petersburg, Our company regards "reasonable prices, efficient production time and good after-sales service" as our tenet. We hope to cooperate with more customers for mutual development and benefits. We welcome potential buyers to contact us.
  • The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By John biddlestone from Rome - 2018.06.12 16:22
    The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Michaelia from Russia - 2018.06.19 10:42