Free sample for Lower Limbs Screw - Multi-axial Distal Lateral Tibia Locking Plate-5.0 system – Shuangyang

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We insist on offering high-quality production with great enterprise concept, honest product sales and also the finest and fast service. it will bring you not only the superior quality solution and huge profit, but the most significant should be to occupy the endless market for Cerclage Wire, Cranial Surgical Plate, Maxillofacial Y Plate, Standing still today and looking into the future, we sincerely welcome customers all over the world to cooperate with us.
Free sample for Lower Limbs Screw - Multi-axial Distal Lateral Tibia Locking Plate-5.0 system – Shuangyang Detail:

Multi-axial Distal Lateral Tibia Plateau Locking Plate

Features:  

1. Multi-axial ring design for proximal part can be adjustment the angel to meet the clinic demand;

2. Top quality titanium and advanced processing technology; 

3. Low profile design helps reduce soft tissue irritation;  

4. Surface anodized; 

5. Anatomical shape design; 

6. Combi-hole can be choosing both locking screw and cortex screw; 

detail (2)

Indication:

Orthopedic implant of multi-axial distal lateral tibia plateau locking plate is suitable for tibia middle and lower end.

Used for Φ5.0 locking screw, Φ4.5 cortex screw, Φ6.5 cancellous screw, matched with 5.0 series surgical instrument set.

Multi-axial Distal Lateral Tibia Plateau Locking Plate Specification

Order code

Specification

10.14.34.05101000

Left 5 Holes

121mm

10.14.34.05201000

Right 5 Holes

121mm

*10.14.34.07101000

Left 7 Holes

157mm

10.14.34.07201000

Right 7 Holes

157mm

10.14.34.09101000

Left 9 Holes

193mm

10.14.34.09201000

Right 9 Holes

193mm

10.14.34.11101000

Left 11 Holes

229mm

10.14.34.11201000

Right 11 Holes

229mm

Distal Lateral Tibia Plateau Locking Plate

Features:  

1. Surface anodized;

2. Low profile design helps reduce soft tissue irritation;  

3. Anatomical shape design; 

4. Combi-hole can be choosing both locking screw and cortex screw; 

Indication:

Distal Lateral Tibia Plateau Locking Plate surgical implant is suitable for tibia middle and lower end.

Used for Φ5.0 locking screw, Φ4.5 cortex screw, Φ6.5 cancellous screw, matched with 5.0 series medical instrument set.

Distal Lateral Tibia Plateau Locking Plate Specification

Order code

Specification

10.14.33.05101000

Left 5 Holes

121mm

10.14.33.05201000

Right 5 Holes

121mm

*10.14.33.07101000

Left 7 Holes

157mm

10.14.33.07201000

Right 7 Holes

157mm

10.14.33.09101000

Left 9 Holes

193mm

10.14.33.09201000

Right 9 Holes

193mm

10.14.33.11101000

Left 11 Holes

229mm

10.14.33.11201000

Right 11 Holes

229mm


Product detail pictures:

Free sample for Lower Limbs Screw - Multi-axial Distal Lateral Tibia Locking Plate-5.0 system – Shuangyang detail pictures

Free sample for Lower Limbs Screw - Multi-axial Distal Lateral Tibia Locking Plate-5.0 system – Shuangyang detail pictures


Related Product Guide:

We enjoy an extremely good status among our prospects for our great merchandise top quality, competitive price and the ideal service for Free sample for Lower Limbs Screw - Multi-axial Distal Lateral Tibia Locking Plate-5.0 system – Shuangyang, The product will supply to all over the world, such as: Congo, Boston, Oman, We welcome you to visit our company & factory and our showroom displays various products and solutions that will meet your expectations. Meanwhile, it is convenient to visit our website. Our sales staff will try their best to supply you with the best services. If you will need more information, please do not hesitate to contact us via E-mail, fax or telephone.
  • We have worked with many companies, but this time is the best,detailed explanation, timely delivery and quality qualified, nice!
    5 Stars By ron gravatt from Bangladesh - 2017.12.19 11:10
    As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Jocelyn from Thailand - 2017.02.28 14:19