Fixed Competitive Price Facial Operation Titanium Screw - Multi-axial Lateral Tibia Plateau Locking Plate-5.0 system – Shuangyang Detail:
Multi-axial Lateral Tibia Plateau Locking Plate
Features:
1. Multi-axial ring design for proximal part can be adjustment the angel to meet the clinic demand;
2. Titanium and advanced processing technology;
3. Low profile design helps reduce soft tissue irritation;
4. Surface anodized;
5. Anatomical shape design;
6. Combi-hole can be choosing both locking screw and cortex screw;
Indication:
Multi-axial lateral tibia plateau locking plate medical implant is suitable for
lateral tibia fracture.
Used for Φ5.0 locking screw, Φ4.5 cortex screw, Φ6.5 cancellous screw, matched with 5.0 series surgical instrument set.
Multi-axial Lateral Tibia Plateau Locking Plate Specification
Order code |
Specification |
|
10.14.31.03101000 |
Left 3 Holes |
100mm |
10.14.31.03201000 |
Right 3 Holes |
100mm |
10.14.31.05101000 |
Left 5 Holes |
136mm |
10.14.31.05201000 |
Right 5 Holes |
136mm |
*10.14.31.07101000 |
Left 7 Holes |
172mm |
10.14.31.07201000 |
Right 7 Holes |
172mm |
10.14.31.09101000 |
Left 9 Holes |
208mm |
10.14.31.09201000 |
Right 9 Holes |
208mm |
10.14.31.11101000 |
Left 11 Holes |
244mm |
10.14.31.11201000 |
Right 11 Holes |
244mm |
Lateral Tibia Plateau Locking Plate
Features:
1. Titanium material and advanced processing technology;
2. Low profile design helps reduce soft tissue irritation;
3. Surface anodized;
4. Anatomical shape design;
5. Combi-hole can be choosing both locking screw and cortex screw;
Indication:
Surgical implant of lateral tibia plateau locking plate is suitable for lateral tibia fracture.
Used for Φ5.0 locking screw, Φ4.5 cortex screw, Φ6.5 cancellous screw, matched with 5.0 series medical instrument set.
Lateral Tibia Plateau Locking Plate Specification
Order code |
Specification |
|
10.14.30.03101000 |
Left 3 Holes |
100mm |
10.14.30.03201000 |
Right 3 Holes |
100mm |
10.14.30.05101000 |
Left 5 Holes |
136mm |
10.14.30.05201000 |
Right 5 Holes |
136mm |
10.14.30.07101000 |
Left 7 Holes |
172mm |
10.14.30.07201000 |
Right 7 Holes |
172mm |
10.14.30.09101000 |
Left 9 Holes |
208mm |
10.14.30.09201000 |
Right 9 Holes |
208mm |
10.14.30.11101000 |
Left 11 Holes |
244mm |
10.14.30.11201000 |
Right 11 Holes |
244mm |
Product detail pictures:
Related Product Guide:
We are convinced that with joint efforts, the business between us will bring us mutual benefits. We can assure you product quality and competitive price for Fixed Competitive Price Facial Operation Titanium Screw - Multi-axial Lateral Tibia Plateau Locking Plate-5.0 system – Shuangyang, The product will supply to all over the world, such as: French, Swansea, Adelaide, Custom orders are acceptable with different quality grade and customer's especial design. We are looking forward to establish the good and successful cooperation in business with long terms from the customers of all over the world.